Email:sales@lc-electric.cn

THERMOCOUPLE -LCTC029

Date: 2015-09-14   Views: 286



Introduction

Applied to hot runner  system,Equip to armored thermocouple out of heating ring and equipped with controlling meter.Measureing and  controlling temperature of heating object,it’s a hard entity which is pulled by temperature measurer ,insulation material and materl protective tube ,the feature is small diameter ,free bending ,pressure-proof,shake-proof ,fast thermal response and high reliability .It;s the best outlay themperature sensor of hot runner molding .

Thermocouple  graduation

Standard :J  type  armored  ,J type KAPTON insulation compensationg lead wire

Optional : K   E   type armored ,K  E type compensating lead wire

Armored thermocouple diameter :  1.0mm    1.5mm   2.0mm   2.5mm. optiomal  1.6mm and so on

Measuring terminal form:insulation .optional case contact ,washer

Measurment accuracy :±2.5 or ±0.75%t

Withstand voltage :400v 0.5Ma

Bending radius:5 x armored thermoucple diameter

Compensating lead wire :KAPTON  insulation,optional glass fiber insulation,stainless braided tube shield ,Multi strand core of cable  0.2mm,optional 0.5mm

Max temperature of connection parts : 600