Thermocouple /
THERMOCOUPLE -LCTC042
Date: 2017-04-29 Views: 346
Introduction
Applied to hot runner system,Equip to armored thermocouple out of heating ring and equipped with controlling meter.Measureing and controlling temperature of heating object,it’s a hard entity which is pulled by temperature measurer ,insulation material and materl protective tube ,the feature is small diameter ,free bending ,pressure-proof,shake-proof ,fast thermal response and high reliability .It;s the best outlay themperature sensor of hot runner molding .
Thermocouple graduation
Standard :J type armored ,J type KAPTON insulation compensationg lead wire
Optional : K E type armored ,K E type compensating lead wire
Armored thermocouple diameter : 1.0mm 1.5mm 2.0mm 2.5mm. optiomal 1.6mm and so on
Measuring terminal form:insulation .optional case contact ,washer
Measurment accuracy :±2.5 ℃ or ±0.75%t
Withstand voltage :400v 0.5Ma
Bending radius:5 x armored thermoucple diameter
Compensating lead wire :KAPTON insulation,optional glass fiber insulation,stainless braided tube shield ,Multi strand core of cable 0.2mm,optional 0.5mm
Max temperature of connection parts : 600℃